Support Center / Therapies & Operation / What the Hydro + Microbubble Schematic Shows: Two Pumps, a Pressure Tank, an LED Control Box and Two Dedicated Lines (Stainless and Outward Door Tubs)
Back to Therapies & Operation

What the Hydro + Microbubble Schematic Shows: Two Pumps, a Pressure Tank, an LED Control Box and Two Dedicated Lines (Stainless and Outward Door Tubs)

Updated September 2026

This page explains the Hydro Therapeutic Massage + Microbubble Therapy component diagram published for Ella's stainless steel inward-swing door and outward-swing door walk-in tubs. It comes from the official schematic hydromicrobubblepdf_compressed.pdf, revision dated 01-16-26, which prints "Available With: Stainless Steel, Outward Door." The drawing shows two pumps, a pressure tank, an in-line heater, an ozone generator, a chromatherapy light with its own control box, and two dedicated electrical lines. If you want to understand what your electrician is wiring, or where to look when the bubbles stop, this is the map.

Which Tubs This Diagram Lists

The "Available With" box names two door families rather than individual models: Stainless Steel, meaning the inward-swing tubs with the brushed stainless steel and frosted glass door, and Outward Door, meaning the tubs with the plastic composite and tempered glass door that swings outward. Any model in either family that is offered with the Hydro Massage + Microbubble package uses this drawing. To see which models list that package, read therapy package combinations by model. The Front Entry has its own version of this diagram with fewer components.

The Six Numbered Components

The legend numbers six components, repeated here exactly as printed.

NumberComponentPrinted details
1Hydro Foot Massage SystemHydro Pump; Hydro Massage Air Flow Intensity Control; ON/OFF Button
2Infusion Microbubbles / Micro Bubble Therapy SystemMicrobubble Pump; Pressure Vessel; ON/OFF Button
3In-Line Water HeaterControl Box
4Electronic Component ControllerControl Box
5Ozone GeneratorOzone Sanitation System
6Led LightChromatherapy

The first item is printed as "Hydro Foot Massage System," yet the drawing labels the pump it points to as the Seat Jets Hydro Pump. Read item 1 as the tub's hydro massage system; your model's spec sheet gives the exact split of seat, foot, and calf jets.

The Hydro Circuit with Heater and Ozone

The hydro side is drawn as a chain. The Hydro Massage Push Control and the Air Flow Hydro Massage Intensity Dial Control sit on the deck. Pressing the push control signals a Relay Switch, which starts the Seat Jets Hydro Pump. Water leaves the pump "Out To Hydro Jets," passes through the In-Line Water Heater, and arrives at the hydro jets. The heater is wired through the control box and operates only while the pump is running, maintaining the temperature of the circulating water. The Ozone Generator is drawn with the arrow "Ozone Out to Hydro System," injecting ozone into this loop for sanitation without any bather control. An Air Hose from the intensity dial feeds air into the hydro system, which is how turning the dial changes how firm the jets feel.

The Microbubble Circuit

The microbubble side is completely separate, printed as: Infusion Microbubbles Push Control, to Relay Switch, to Water Pump, Water in, to MicroBubbles Pressure Tank, to Micro Bubbles Out to Jet. The push control on the deck closes its relay, the water pump draws tub water in, the pressure tank (the legend's Pressure Vessel) combines that water with air under pressure, and the water releases through the microbubble jet as a cloud of tiny bubbles that turns the bath cloudy white. This water never passes through the heater or the ozone generator. What the therapy feels like and how to use it is covered in microbubble infusion therapy.

The LED Has Its Own Control Box

A detail that sets this diagram apart is the chromatherapy light. The LED Light is drawn with its own push control and its own LED Control Box, separate from the Electronic Component Controller that runs the pumps and heater. In practice this means a dark light does not point to the pump control box, and a dead pump does not point to the LED box. The LED chromatherapy light is rated 0.5A and runs on its own transformer and control; ozone sterilization is a separate 0.04A. Colors, modes, and light troubleshooting are in the chromatherapy lights guide.

Electrical Printed on the Diagram

Two outlets are printed, #1 and #2, each labeled Wall Outlet, GFCI Protected, Dedicated Line, 20 AMP, 120 Volts. The hydro system with its heater and ozone generator runs from one line and the microbubble system from the other. All components are marked Electrical 110V, and the page carries the disclaimer "Please View Specifications for Electrical Amperage (A), Voltage (V) and Wattage (W)." Use your model's spec sheet for pump, heater, and microbubble pump amperage, and see electrical requirements by model for the overall picture.

Failure Chain to Check

Because the diagram shows each system as a chain, it also gives you the order to check things in.

  1. Confirm both GFCI outlets are live and reset. With two dedicated lines, one system can run perfectly while the other is dead because only its breaker or receptacle tripped.
  2. Make sure the water covers the jets, the microbubble port, and the intake before pressing either push control so the pumps can prime.
  3. For the hydro massage, follow push control, relay switch, seat jets hydro pump, heater, jets. No pump sound points to the control, relay, or the pump's cord.
  4. For the microbubbles, follow push control, relay switch, water pump, pressure tank, jet. A pump that runs with clear water points to the pressure tank or the jet, downstream of the pump.
  5. For the light, check its own push control and the LED Control Box rather than the pump box.
  6. Note your serial number and contact your Ella dealer or the team at (800) 480-6850, or open a request at ellasbubbles.com/support. The detailed microbubble path is in microbubble not producing bubbles.

Download the official document: Hydro Therapeutic Massage + Microbubble Therapy Component Diagram

Common Questions

Why does this package need two dedicated 20 amp lines?
The diagram prints two outlets, #1 and #2, each GFCI Protected, Dedicated Line, 20 AMP, 120 Volts. The hydro system with its heater and ozone generator runs on one, and the microbubble water pump with its pressure tank runs on the other, so each pump circuit has its own protected supply.
Which tubs does this diagram apply to?
It prints "Available With: Stainless Steel, Outward Door," so it covers any inward-swing stainless steel door tub or outward-swing door tub with the Hydro Massage + Microbubble package. The Front Entry uses its own separate drawing.
Does the LED light run through the same control box as the pumps?
No, the LED chromatherapy light does not run through the same control box as the pumps. The Hydro Therapeutic Massage + Microbubble Therapy component diagram shows the LED Light with its own push control and its own dedicated LED Control Box, which is separate from the Electronic Component Controller that operates the pumps and the in-line heater. Therefore, if your LED light is out but the hydro massage or microbubble pumps are running, you should check the light's own control box and push control, not the pump controller. Light Chromatherapy: Using the LED Colors and Fixing a Light That Will Not Turn On provides more details on troubleshooting the LED light.
Is microbubble water heated by the in-line heater?
No, the microbubble water is not heated by the in-line heater. The in-line water heater is specifically located within the hydro massage loop, positioned between the Seat Jets Hydro Pump and the hydro jets, to maintain the temperature of the circulating hydro massage water. The microbubble system operates on a completely separate circuit, where water flows from the microbubble water pump to the MicroBubbles Pressure Tank and then out through the microbubble jet, without passing through the heater or the ozone generator. Infusion Microbubble Therapy: What It Does and Which Tubs Offer It explains more about the microbubble therapy.
Why is item 1 called Hydro Foot Massage System?
That is how the legend is printed, but the pump it points to is labeled the Seat Jets Hydro Pump on the drawing. Treat item 1 as your tub's hydro massage system and use your model's spec sheet for the seat, foot, and calf jet counts.
Do I control the ozone generator?
No, you do not control the ozone generator directly. The Hydro Therapeutic Massage + Microbubble Therapy component diagram shows the Ozone Generator with an arrow labeled "Ozone Out to Hydro System," indicating that it automatically injects ozone into the hydro massage loop for sanitation. The ozone generator operates whenever the hydro massage system is running, and there is no separate ozone button or control on the tub's deck for bathers to activate or deactivate it.
What should I check first if the hydro works but the microbubbles do not?
Check the second outlet's GFCI, since the microbubble system is on its own dedicated line. Then follow the chain the diagram shows: push control, relay switch, water pump, pressure tank, jet. If the pump runs but no bubbles appear, contact your Ella dealer or the team at (800) 480-6850.

About this guide. Answers in the Ella’s Bubbles Support Center are compiled from real conversations with tub owners, our technicians’ notes and the product documentation, then reviewed by our team. Tub models and options have evolved over the years, so a detail here may differ slightly from your exact tub. If something looks different on yours, send us your serial number and a specialist will confirm it for your model.

Did this solve your question?

If not, open a ticket and our team will pick it up from here.

Open a Support Ticket