Ella's Bubbles Walk In Tub Blog

Support Center / Therapies & Operation / What the Front Entry Hydro + Microbubble Schematic Shows: Why This Package Needs Two Dedicated Lines

What the Front Entry Hydro + Microbubble Schematic Shows: Why This Package Needs Two Dedicated Lines

This page explains the Hydro Therapeutic Massage + Microbubble Therapy component diagram drawn for the Ella Front Entry walk-in tub, and in particular why this package is wired to two dedicated electrical lines. It comes from the official schematic hydro-microbubble-front-entry.pdf, revision dated 02-04-26, which prints "Available With: Front Entry." We also reference the Front Entry spec sheet for the pump and jet figures the diagram sends you to. If your electrician has asked why there are two outlets on the plan, or your bubbles have stopped and you want to know what to check, start here.

A Two-Outlet Diagram for One Model

Unlike the Front Entry Air + Hydro drawing, which prints a single outlet, this diagram prints two: Outlet #1 and Outlet #2, each labeled Wall Outlet, GFCI Protected, Dedicated Line, 20 AMP, 120 Volts. The reason is simple. The hydro massage system and the microbubble system are two separate pump circuits, each with its own relay and its own push control, and each pump is a significant load in its own right. Splitting them across two dedicated lines keeps each system on its own protected circuit. The Front Entry itself is profiled in the Front Entry walk-in tub profile.

The Four Numbered Components

The legend numbers four components. The labels are repeated exactly as printed.

NumberComponentPrinted details
1Hydro Foot Massage SystemHydro Pump; Hydro Massage Air Flow Intensity Control; ON/OFF Button
2Infusion Microbubbles / Micro Bubble Therapy SystemMicrobubble Pump; Pressure Vessel; ON/OFF Button
3In-Line Water HeaterControl Box
4Ozone GeneratorOzone Sanitation System

A note on the first label: the legend prints it as "Hydro Foot Massage System," while the Front Entry spec sheet lists the hydro system's 13 jets as 11 seat jets and 2 calf jets. The drawing shows the hydro pump feeding the seat jets, so read item 1 as the tub's single hydro massage system. There is no LED chromatherapy light on this diagram, which matches the Front Entry spec sheet's note that no package for this model includes one.

The Hydro Loop

The hydro side is drawn as a chain. The Hydro Massage push control on the deck signals a Relay Switch, which starts the Hydro Pump. Water leaves the pump "Out To Hydro Jets," passes through the In-Line Water Heater, and reaches the hydro jets. The heater is wired through the control box and runs only while the pump runs, so it maintains the temperature of the circulating water. The Ozone Generator is drawn with the arrow "Ozone Out to Hydro System," so ozone sanitation is injected into this loop automatically; no ozone control for the bather appears on the diagram. An Air Hose links the Air Flow Hydro Massage Intensity Dial Control to the hydro system, which is how the dial lets you soften or strengthen the jets by mixing in air.

The Microbubble Loop

The microbubble side is a separate circuit with its own path, printed as: Water in, to Water Pump, to MicroBubbles Pressure Tank, to Micro Bubbles Out to Jet. The Infusion Microbubbles Push Control on the deck signals its own Relay Switch, which starts the water pump. The pump drives water into the pressure tank (the legend's Pressure Vessel), where water and air are combined under pressure, and the water then releases through the microbubble jet as a cloud of tiny bubbles that turns the bath cloudy white. Nothing on this loop passes through the heater or the ozone generator. What the therapy feels like and how to use it is covered in microbubble infusion therapy.

Electrical Printed on the Diagram

Two outlets are printed, #1 and #2, each Wall Outlet, GFCI Protected, Dedicated Line, 20 AMP, 120 Volts. Components are marked Electrical 110V, and the page carries the disclaimer "Please View Specifications for Electrical Amperage (A), Voltage (V) and Wattage (W)." The Front Entry spec sheet supplies those figures.

SystemPrinted specification
Hydro MassagePump 7A; Intensity Dial Air Control; Ozone Sterilization 0.04A; 13 jets (11 Seat Jets, 2 Calf Jets); On/Off Push Control; In-line Water Heater 6A 650W
Microbubble Therapy1 HP Pump 7.3A; Pressure Vessel; On/Off push control; Agitator Valve

The spec sheet notes that the AMP value for each pump may change based on availability, so confirm with your Ella dealer or the team at (800) 480-6850 before the circuits are sized. A model-by-model summary is in electrical requirements by model.

Checks When Bubbles Stop

The diagram gives you the order to check things in, because the microbubble circuit is a chain: push control, relay switch, water pump, pressure tank, jet.

  1. Confirm Outlet #2's GFCI has not tripped. Because the two systems are on separate lines, the hydro massage can run normally while the microbubble line is dead. Reset the receptacle or breaker.
  2. Make sure the water covers the microbubble port and the intake before pressing the Infusion Microbubbles push control; the water pump needs water to prime.
  3. Press the push control and listen behind the access panel for the water pump. Silence points to the push control, its relay, or the pump's cord and connection.
  4. If the pump runs but the water stays clear, the trouble is downstream of the pump, in the pressure tank or the jet. Do not open the pressure vessel yourself.
  5. Note the serial number and contact your Ella dealer or the team at (800) 480-6850, or open a request at ellasbubbles.com/support. The full troubleshooting path is in microbubble not producing bubbles.

Download the official document: Hydro Therapeutic Massage + Microbubble Therapy Component Diagram (Front Entry)

Common Questions

Why does my Front Entry microbubble tub need two outlets?
The diagram prints two dedicated lines because the hydro massage system and the microbubble system are separate pump circuits, each with its own relay and push control. Each outlet is GFCI Protected, Dedicated Line, 20 AMP, 120 Volts.
Can both outlets share one 20 amp circuit?
No. The diagram labels each outlet as a Dedicated Line, meaning its own breaker. Give your electrician the diagram and the spec sheet amperage so both circuits are sized and protected correctly.
Does the microbubble water go through the heater?
No. The heater sits in the hydro loop between the hydro pump and the hydro jets. The microbubble path runs from the water pump to the pressure tank to the microbubble jet, on its own circuit.
Why does the legend say Hydro Foot Massage when my jets are in the seat?
That is how the legend is printed on this diagram. The Front Entry spec sheet lists the hydro system as 13 jets, 11 seat and 2 calf, and the drawing shows the hydro pump feeding the seat jets, so item 1 is simply the tub's hydro massage system.
Is there a chromatherapy light on the Front Entry with this package?
No. The spec sheet prints "LED Chromatherapy Light NOT Included" for every Front Entry package, and no LED component appears on this diagram.
What is the pressure vessel and can I service it?
It is the MicroBubbles Pressure Tank where water and air are combined under pressure before the microbubbles release at the jet. It is not a user-serviceable part; if the pump runs but no bubbles appear, contact your Ella dealer or the team at (800) 480-6850.

Did this solve it?

If not, open a ticket and our team will pick it up from here.

Open a Support Ticket