A breaker or GFCI that keeps tripping when your Ella's Bubbles walk-in tub runs is almost always telling you one of two things: the circuit is carrying more than it was sized for, or a component is leaking current to ground. The first is a sizing question your electrician solves by adding the dedicated 20A, 120V GFCI line your package requires. The second is a safety signal: if a GFCI trips and will not reset, switch the power off and do not use the tub until a licensed electrician has found and corrected the cause. This article explains how the circuits should be laid out, what each component draws, and how to tell an overload from a fault.

Chapters in this video
- 0:00 Electrical Components Are Marked Ella's Bubbles ensures all electrical components are clearly marked and easily accessible for installation.
- 0:13 Dedicated GFCI Protected Outlets Your contractor connects the tub to your home's power supply using dedicated GFCI protected outlets.
- 0:25 GFCI Protected Breakers The breaker box must utilize GFCI protected breakers with the appropriate amperage value for your tub's components.
- 0:40 Enjoy Your Walk-In Tub Proper installation provides years of reliable, trouble-free walk-in tub enjoyment.
The video covers the rules your contractor follows when connecting the tub to your home's power: dedicated GFCI protected outlets must be used, the tub cannot share a circuit with any other appliance, the breaker box must also use GFCI protected breakers, and the amperage provided depends on the number and type of components in your tub. All pumps, heaters, and electrical components are ETL certified, clearly marked, and easily accessible. Watch: Ella's Bubbles: Proper Electrical Requirements For Installation with chapters and a full transcript.
How Many Dedicated Lines Your Package Needs
Nearly every Ella tub with pumps is specified for dedicated 20A, 120V GFCI protected lines, and the count depends on the therapy package:
- One line: Hydro only; Air only (LayDown); Microbubble only (LayDown); Air + Hydro on a single-seat tub.
- Two lines: Hydro + Microbubble; Air + Hydro + Hydro Foot; and the single-seat variants that add Microbubble or a Heated Seat.
- Three lines: Shak and Big4One with the digital Air + Hydro + Hydro Foot + Micro package, and the full two-seat package (Air + Hydro + Hydro Foot + Micro + Heated Seat).
- 15A exceptions: The Flow is the only Ella tub specified for a 15A GFCI outlet. A soaking tub with only the optional heated seat, and no pumps, needs a 15A, 120V line.
Every Ella walk-in tub runs on standard 120V household power, not 220V or 240V. A 15A circuit may be enough for a lighter package, but 20A is the published standard and the recommended choice. Please confirm your exact package with us before the electrician runs the line. Our article on electrical requirements by model lists the circuits for each configuration, and outlet placement and cord reach covers where the receptacles should go.
What Each Component Draws
Adding up the published amp ratings of everything that runs at once shows why one circuit suits one package and trips on another. Typical ratings from the specification sheets:
- Hydro pump: 5A to 9A depending on model (8.1A on the Standard family; 9A seat pumps on Shak, Big4One, Tub4Two, and Big4Two).
- In-line water heater: 5.5A to 9A depending on model; it runs only while the hydro pump runs.
- Air massage pump: 4.5A on most models, 6.4A on Ultra and Elite.
- Microbubble pump: 1 HP, 7.3A (10A on the Standard60 H2 system).
- Heated Seat and Backrest: 4A.
Amp values for pumps may change based on availability, so verify against your own specification sheet or with us at (800) 480-6850. A hydro pump, in-line heater, and air pump together already use most of a 20A circuit, which is why adding a heated seat or a second pump moves the package into the two-line column. A tub that runs fine on hydro alone but trips when everything is on is describing an overload, not a defect.
The 20A Plug
Some master control boxes (the type that runs the massage systems together with a heated seat) carry a 20A plug with one blade turned sideways, which needs a 20A receptacle. Others use a standard three-prong 15A style plug. Either way the line must be dedicated and GFCI protected, and extension cords must never be used. Which cord plugs where shows how to identify each cord after installation.
GFCI Will Not Reset: Stop and Call an Electrician
Push the GFCI "test" button and then "reset." If the GFCI fails to operate this way, there is ground current flow or a device malfunction, which indicates the possibility of electrical shock. Turn the power off and do not use the tub until a licensed electrician has identified and corrected the source. Three situations deserve special mention:
- A burning smell together with a tripping GFCI is a reason to leave the power off and open a ticket right away rather than keep testing.
- The GFCI trips the instant the main cord is plugged in, even with every pump and wire disconnected from the control box and a new GFCI breaker installed, points to the control box or its cord rather than the circuit. Please do not keep resetting it. Send us your serial number and a description so our technical team can verify the box under your warranty terms; control box diagnosis and replacement explains what happens next.
- A pump that trips the breaker and now rattles or sounds abnormal needs to stay off until our team has looked at it.
After a Trip: Getting the Tub Running Again
- Reset the breaker in your panel, then also press the reset button on the GFCI outlet serving the tub. They are separate devices and both can trip.
- Look at the control box behind the access panel. A green LED shows that power is reaching the box. No green light means the problem is upstream in the outlet, cord, or circuit.
- If power is present but several functions still misbehave after a power event, follow our control box reset guide step by step. After a storm or outage, nothing works after a power outage puts the checks in order.
Our published documentation does not describe any user-serviceable fuse or separate GFCI inside the control box; the reset points are the breaker, the GFCI outlet, and the control box reset procedure.
Have the Electrician Confirm the Basics

This short video covers grounding: every Ella tub ships with ground wires on all electrical components and on the frame, and the installer must secure a proper ground connection to local and state code. An ungrounded frame is one of the things an electrician looks for when tripping continues. Watch: Proper Grounding of Your Walk-In Tub with a full transcript.
The warranty activation checklist requires a licensed electrician, a dedicated GFCI breaker, and a grounded frame, so an electrician's visit is the right move whenever tripping continues. Ask them to confirm that each tub cord is on its own dedicated GFCI protected line, that the line count matches the package, and that no extension cord is in use. If the circuits are correct and the GFCI still trips, unplugging the components one at a time identifies the one at fault, and that is the detail to include in your ticket. Our technical support team is glad to talk directly with your electrician at (800) 480-6850; electrical common questions covers 15 versus 20 amps and outlet versus breaker in more depth.
Replace the Breaker Before Suspecting the Tub
When a pump or the foot jets trip a breaker on a correctly sized dedicated 20A circuit, the first thing to change is the breaker itself. Breakers vary a great deal in quality. Lower-cost units can trip on the inrush current of a pump motor starting even though the running load is well inside 20 amps, and a brand-new breaker from the same budget line can behave exactly like the one it replaced. Ask your electrician to install a better-quality breaker of the same 20A rating. Several customers with back jets working and foot jets tripping the breaker have solved it this way.
Moving up to a 30A breaker is not the answer. Each hydro pump and the in-line heater it feeds run well inside a dedicated 20A circuit, and a larger breaker does not help a pump start. It only removes the protection the circuit is supposed to provide.
Next, have your electrician confirm that the foot pump has its own circuit. On tubs with independent hydro foot massage the foot jets run on a separate pump, and it must not be landed on a circuit already carrying the main pump and heater. Check the circuits against your model's specification sheet, and see how many GFCI circuits the tub needs for the line count.
If the pump still trips through a good 20A breaker on its own circuit, the fault is on the tub side. Technical support is available to your electrician by phone while they isolate the pump, its switch and its control from the house wiring, following the same approach as the breaker check and the hose swap test. A faulty pump, switch or control box is replaced under the lifetime parts warranty after you open a ticket with your model, serial number, which function trips and when, and what your electrician found. A licensed electrician installs the replacement.
A system that switches itself on with nobody touching the controls and then trips the main breaker also points to a fault. Do not confuse that with the air system's Auto Purge, which starts by itself about 20 minutes after the air pump is turned off, runs for 120 seconds to blow residual water out of the air lines, cannot be stopped, and is normal even if it begins while you are still in the tub. Random starts at other times that trip a breaker are not normal.
Related Guides
- Pump Shuts Off After a Few Minutes Without Tripping the Breaker: The 20-Minute Timer, Overheating, and Isolating Each Pump
- Burning or Hot Plastic Smell From Your Walk-In Tub: Isolating the Pump or Control Box
- A Terminal Screw on the Electrical Connection Bar Was Loose and Sparked: Is the Tub Still Safe?
- In-Line Heater Light Stays Off and the Water Cools: How to Check It and Get a Replacement
- GFCI Trips Only When the Air or Hydro Pump Starts: Test the GFCI First, Then Look for Water Under the Tub
- T-Shaped Plug Does Not Fit the Outlet: The 20 Amp Plug on Your Walk-In Tub Cord
Common Questions
My tub trips the breaker when all features run. What is wrong?
The GFCI will not reset after a trip. What should I do?
Do I need a GFCI breaker and a GFCI outlet?
Can both plugs share one GFCI?
Is there a fuse or reset inside the tub?
I reset the breaker but the tub still does not turn on.
Is the tub 220V? My panel is 220.
The breaker trips while the tub is not in use. Why?
Can I use a nearby 15A line with little else on it?
For anything specific to your model or package, open a ticket at ellasbubbles.com/support with your serial number and your electrician's questions, or call (800) 480-6850.