Ella's Bubbles Walk In Tub Blog

Support Center / Troubleshooting & Repairs / Nothing Works After a Storm or Power Outage: Breaker, GFCI Under the Tub, the Control Box, and Why Motors Have No Reset Button

Nothing Works After a Storm or Power Outage: Breaker, GFCI Under the Tub, the Control Box, and Why Motors Have No Reset Button

Updated September 2026

When a storm or power outage leaves your Ella walk-in tub completely silent, the cause is almost always upstream of the tub itself: a tripped breaker at the panel, a tripped GFCI (which is often mounted under the tub behind the access panel), or a control box that lost power. Work through those three in order before assuming anything is broken. Pump motors do not have a reset button, so there is nothing to press on the motor itself; if power reaches the blue control box and nothing runs, the box or its relay may have been damaged, and the team can help from photos.

Check These Three Things in Order

  1. The dedicated breaker(s) at your panel. Every Ella tub runs on one or more dedicated GFCI protected lines (20 amp, 120 volt on nearly every model), and a storm often trips them. Switch the breaker fully off, then back on. If it pops again the instant you reset it, stop there and call a licensed electrician; the breaker itself may have failed. Circuit counts by package are in electrical requirements by model.
  2. The GFCI reset. The GFCI protection is sometimes at the breaker and sometimes at the outlet. On many installations the GFCI outlet sits under the tub, behind the front apron access panel, precisely so you can reset it without a trip to the basement. Remove the access panel, find the GFCI, and press Reset. If it will not hold, or it trips the moment a pump starts, leave the power off and have an electrician look at it: a GFCI that fails test or reset means ground current is flowing, and the tub should not be used until it is corrected.
  3. The green light on the blue control box. A steady green light on the box under the tub means power is reaching it. No light at all means the box is not getting power (go back to steps 1 and 2, then check that the box's own cord is plugged in). If the light is on but nothing responds, see the sections below.

This short walkthrough uses an Ultimate with three pumps. The control box runs two of them (the air pump and one water pump), while the third pump is powered together with the in-line heater on its own line. The technician makes the two checks that solve most "nothing works" calls: confirm each pump cord is actually plugged in, and confirm the green indicator on the control box is lit. On a multi-pump tub, trace every pump cord back to its outlet, not just the first one you find.

Why the Motor Has No Reset Button

Owners often go looking for a thermal reset on the pump housing. Ella pump motors do not have one; the tub's reset points are the breaker, the GFCI, and the control box configuration button. When a customer described this exact situation after a summer thunderstorm, the team's answer was direct: the motors have no reset, so it is either a tripped breaker or a control box that has burned out.

Tubs with More Than One Circuit

Many Ella tubs use two or three dedicated lines, and a storm does not always trip all of them, which is why one function can survive while others go dark. Which functions share a line depends on the package. On a common dual-line layout the air pump, foot hydro pump, LED light, and heated seat all run through the blue control box on one line, while another hydro pump sits on a separate line; two-seat tubs with the full package use three lines. If the seat jets run but the foot jets, air, and light are all dead together, the shared circuit for those functions has tripped: reset that breaker and that GFCI. Check every breaker and every GFCI before you conclude a component is gone. The article which cord plugs where shows what each box and cord does.

Power Reaches the Box but Nothing Runs

If the green light is steady, the pump cords are plugged in, and the buttons still do nothing, a storm may have damaged the relay inside the control box or the box itself. Two tell-tale signs: the air pump comes on by itself and keeps running well past the normal 120 second Auto Purge, or a button that used to click is now silent. The first thing to try is a full reset of the box, shown below. If the reset does not bring things back, the team can arrange a tested replacement box. Diagnosis details are in blue control box has no power light.

The reset video walks through the sequence: unplug the box and watch the green light go out, label and remove every air tube and electrical connection, unplug the pumps, then restore power and watch the light flash four times before going solid. Hold the config button until the light cycles through one, two, three, and four blinks, release it, and wait for solid green. Reconnect each line to its labeled port, plug the pumps in, and test every function. The written steps are in the control box reset guide.

If It Smells Burnt or the GFCI Trips Instantly

A burning smell, a scorched spot on the box, or a GFCI that trips the moment you reset it is an electrical fault. Leave the power off at the breaker, do not keep resetting, and open a ticket at ellasbubbles.com/support or call (800) 480-6850 with clear photos of the control box (labels, cords, any discoloration) and a short description of what happened and when. When a replacement box is needed the team ships a tested unit with a return label so the old box can come back for diagnosis.

What About Coverage for Storm Damage?

The team evaluates the cause of any failure from your photos and description; a note from your electrician about what they found is helpful. This article does not decide coverage either way; the people who look at your specific tub do. The process for reporting a failed part is in how to start a warranty claim.

Preventing the Next One

Whether a whole-house surge protector or one on the tub's circuits makes sense for your home is a question for your licensed electrician. After any outage, glance at the green light on the control box before your next bath.

Common Questions

After a storm nothing on the tub works. What do I check first?
Start at your electrical panel and reset the dedicated breaker that serves the tub, switching it fully off and then back on. Next, find the GFCI, which on many installations sits under the tub behind the front apron access panel, and press Reset. Finally, look for a steady green light on the blue control box under the tub, which confirms that power is reaching it. Working through those three checks in order resolves most silent tubs after an outage.
Is there a reset button on the pump motor?
No. Ella pump motors do not have a thermal reset button, so there is nothing to press on the motor housing itself. The tub's reset points are the breaker at your panel, the GFCI, and the configuration button on the blue control box. If a pump stays silent after those three have been reset, the pump is not getting power or the control box needs attention, rather than the motor needing a reset.
Where is the GFCI if the outlet is behind the tub?
Look behind the access panel on the front apron of the tub. Many installers place the GFCI outlet under the tub in that spot precisely so it can be reset without pulling the tub away from the wall. If you do not find a GFCI outlet there, the GFCI protection may be built into the breaker itself at your panel, so check there as well. If the GFCI will not hold or trips as soon as a pump starts, leave the power off and have a licensed electrician look at it.
The breaker pops again the moment I reset it.
Stop resetting it and call a licensed electrician. A breaker that will not hold while the tub is idle can mean the breaker itself has failed, or that there is a fault that needs to be found with a meter. Repeated resetting will not clear the problem, so leave the power off until the electrician has checked it.
Only some functions died. Is that possible from one storm?
Yes. Many Ella tubs run on two or three dedicated lines, and a storm does not always trip every one of them, so one circuit can go dark while another keeps working. For example, if the seat jets still run but the foot jets, air massage, and light are all dead together, the shared circuit for those functions has tripped. Check every breaker and every GFCI, not just the first one you find, before concluding that a component has failed.
Could the control box be burned out?
It can happen. If the green light is on but nothing responds to the buttons, or the air pump comes on by itself and keeps running well past the normal Auto Purge, the relay inside the box or the box itself may have been damaged by the storm. Try the full control box reset first, shown in the reset video above. If the reset does not bring things back, open a ticket with clear photos of the box and cords, and the team can arrange a tested replacement box with a return label for the old one.
Is surge damage covered?
The team evaluates the cause of any failure from your photos and description on each case, so this article does not decide coverage either way. Send clear pictures of the control box, its labels and cords, and any discoloration, along with a short note on what happened and when. A note from your electrician about what they found is also helpful. The people who review your specific tub will let you know how it will be handled.

Still dark after the breaker, the GFCI, and the control box reset? Open a ticket at ellasbubbles.com/support/new with photos of the control box and your model and serial number, or call (800) 480-6850.

Did this solve it?

If not, open a ticket and our team will pick it up from here.

Open a Support Ticket