Ella's Bubbles Walk In Tub Blog

Support Center / Therapies & Operation / What the Air + Hydro Digital Controller and Heated Seat Schematics Show: Three Variants for the Lounger, Stainless and Outward Door Tubs

What the Air + Hydro Digital Controller and Heated Seat Schematics Show: Three Variants for the Lounger, Stainless and Outward Door Tubs

This page explains three closely related Ella's Bubbles schematics: the Air + Hydro Therapeutic Massage Component Diagram With Digital Controller (air-hydro-digital.pdf), the Air + Hydro Therapeutic Massage + Heated Seat & Back Component Diagram With Digital Controller (air-hydro-digital-heat.pdf), and the push-control Air + Hydro Therapeutic Massage + Heated Seat & Back Component Diagram (air-hydro-heat.pdf). The two digital diagrams carry a revision date of 01-16-26 and list "Available With: Ella Lounger, Stainless Steel, Outward Door." The push-control heated diagram carries a revision date of 10-16-23 and prints no model list. We also draw on the Ella Lounger spec sheet, which explains why that model is named on the digital versions.

Three Diagrams, One Core System

All three drawings describe the same dual jetting package: an air massage blower, a hydro massage pump with an in-line water heater, an ozone generator feeding the hydro loop, and an LED chromatherapy light. What changes from one diagram to the next is how the bather turns things on and whether a heated seat and backrest is part of the tub. Reading them side by side is the easiest way to understand what your installer will find behind the apron and what the controls on your deck actually do.

Variant a: Air + Hydro with Digital Controller

The first diagram replaces the individual deck push buttons with a single Digital Controller. Its legend reads as follows.

NumberComponentPrinted details
1Air Massage SystemRefer to Technical drawing for jet Count; Variable Speed Pump with Auto Purge; ON/OFF Digital Controller
2Hydro Massage SystemHydro Pump; Hydro Massage Air Flow Intensity Control; ON/OFF Digital Controller
3Electronic Component ControllerControl Box
4Ozone GeneratorOzone Sanitation System
5In-Line Water HeaterControl Box
6Led LightChromatherapy

Even with a digital controller, the Air Flow Hydro Massage Intensity Dial Control still appears on the deck. The dial is an air control on an air hose, not an electrical control, so it stays mechanical regardless of which controller family you have. The control box still shows Load 1 and Load 2 for the hydro pump and air pump, with a Relay Switch drawn on the heater loop. The difference between button and touchpad operation is covered in push controls vs digital touchpad.

Variant B: Air + Hydro + Heated Seat & Back with Digital Controller (master Box)

The second diagram adds two components and renames the controller. Items 1 through 6 match Variant A, except that item 3, the Electronic Component Controller, is now printed as a Master Box rather than a Control Box. The additions are:

NumberComponentPrinted details
7Surface Heater PadsHeater Pads
8Surface Key PadON/OFF Push Button

On the drawing, the Surface Heater Pads are shown near the Digital Controller and connect to the Master Box. The Surface Key Pad is a dedicated ON/OFF push button for the heat, so on this variant you use the digital controller for air, hydro, and LED, and a separate button for the heated surface. The heated seat and backrest is an electric surface heater, completely separate from the in-line water heater in the hydro loop. How the pads feel and how to use them is explained in heated seat and backrest.

Variant C: Air + Hydro + Heated Seat & Back with Push Controls

The third diagram is the push-control version of the heated package. Its legend numbers the same eight components, but items 1 and 2 print ON/OFF Push Button instead of ON/OFF Digital Controller, and the deck shows three push controls labeled Hydro Massage, LED Light, and Air Massage plus the intensity dial. The heat has its own Heat Keypad wired to the Master Box, and item 8, Surface Key Pad, is again an ON/OFF Push Button. This drawing prints a revision date of 10-16-23 and does not list which models it is available with. If your tub has push controls and a heated seat, it still describes your configuration; for the model list and any detail that differs between the drawings, the two newer digital diagrams are the current reference.

Why the Lounger Is Named on the Digital Diagrams

The Ella Lounger spec sheet lists its jetting options with the controller type printed next to each one. Air + Hydro is printed as "Digital Controller only, LED Chromatherapy Light Included." Hydro + Hydro Independent Foot Massage, Hydro Massage + Microbubble, and Hydro Massage are each printed as "Push Button only." Because the Lounger's Air + Hydro package always comes with the digital controller, the Lounger appears in the "Available With" list on both digital diagrams, alongside the Stainless Steel and Outward Door families where the digital controller is an option. The Lounger sheet also lists a Heated Seat and Backrest as an optional feature, which is the Variant B configuration. You can read the full model profile in Lounger walk-in tub profile.

Electrical Printed on Each

All three diagrams print the same wall outlet requirement: GFCI Protected, Dedicated Line, 20 AMP, 120 Volts. Every powered component is marked Electrical 110V, and the Air Pump is rated 110-120 V, 4.5 A on each drawing. The heater pads are shown fed through the Master Box; no second outlet is drawn for any of these three configurations. Each page carries the disclaimer "Please View Specifications for Electrical Amperage (A), Voltage (V) and Wattage (W)," so use your model's spec sheet for pump and heater amperage. When you or your installer are checking connections behind the apron, cords, control boxes and connections after install shows what plugs where.

Download the official document: Air + Hydro Therapeutic Massage + Heated Seat & Back Component Diagram With Digital Controller

Common Questions

What is the difference between a Control Box and a Master Box on these diagrams?
They are the same Electronic Component Controller, item 3 in the legend. The diagrams that include the heated seat and back print it as a Master Box because it also feeds the Surface Heater Pads; the plain Air + Hydro digital diagram prints it as a Control Box.
Does the heated seat use the digital controller?
No. On both heated variants the heat has its own control, printed as a Surface Key Pad with an ON/OFF Push Button, and the push-control version also shows a Heat Keypad wired to the Master Box. The digital controller runs the air, hydro, and LED functions.
Why does the Lounger only come with the digital controller for Air + Hydro?
The Lounger spec sheet prints Air + Hydro as "Digital Controller only" while its other packages are "Push Button only." That is why the Lounger is named on the digital diagrams and not on the push-control one.
Do I still get an intensity dial with a digital controller?
Yes. The Air Flow Hydro Massage Intensity Dial Control appears on all three diagrams. It is an air control on an air hose that adjusts the feel of the hydro jets, so it is not part of the electronic controller.
Does adding the heated seat and back require a second outlet?
Not according to these diagrams. Each one prints a single wall outlet, GFCI Protected, Dedicated Line, 20 AMP, 120 Volts, with the heater pads fed through the Master Box. Check your model's spec sheet for total amperage before the electrician sizes the circuit.
Which of the three diagrams should I follow if they disagree?
The two digital diagrams are revision 01-16-26 and the push-control heated diagram is revision 10-16-23, so the newer digital drawings are the current reference. If you are unsure which configuration your tub has, contact your Ella dealer or the team at (800) 480-6850 with your serial number.

Did this solve it?

If not, open a ticket and our team will pick it up from here.

Open a Support Ticket