When jets that worked suddenly stop turning on, restore power first: reset the tub's dedicated breaker, press Reset on the GFCI outlet, and look for a steady green light on the blue control box. If that light is on but the buttons still do nothing, the box has likely lost its configuration, and the control box reset is the step that brings it back. Why Did the Jets on My Walk-In Tub Stop Working? covers the more common power and air hose causes, and this page gives the reset itself from the first disconnect to the last button test.

Rule Out Power and the Air Signal First

The reset means unplugging every line from the box, so it is worth a few quick checks before you begin. Most jets that stop have a simpler cause.

  1. Reset the breaker. Every Ella tub runs on one or more dedicated GFCI protected lines, 20 amp and 120 volt on nearly every model. Switch each of the tub's breakers fully off, then back on. If a breaker pops again right away, stop and call a licensed electrician.
  2. Reset the GFCI. On many installations the GFCI outlet sits under the tub, behind the front access panel, and flipping the breaker does not reset it. Remove the panel and press Reset. A GFCI can trip without the panel breaker moving.
  3. Look at the green light. The blue control box has a small green power LED beside its power inlet. A steady green light means power is reaching the box. No light means the box is not getting power, so check that its cord is pushed all the way in.
  4. Reseat the air hoses. Ella push buttons are pneumatic. Each button sends a puff of air down a thin hose to the box. Pull each hose off its port, let it hang loose for a few seconds, and push it back on firmly. The air lock release guide shows the ports.
  5. Check the water level. The water should be 1 to 2 inches above the highest jets before you press the water button.

One more thing can look like a fault. About 20 minutes after the air pump is switched off, the auto purge runs for 120 seconds to blow water out of the air lines. It cannot be stopped, and the other features will not respond while it runs. Wait for it to finish, then try the button again. The full breaker and GFCI sequence is in How Do I Reset My Ella Walk-In Tub After a Power Outage or GFCI Trip?.

How to Tell the Control Box Reset Is the Right Step

Every deck button and every pump passes through the blue control box, so the green light tells you which way to go.

  • Outlet live, green light dark. The box or its cord is not passing power. A reset will not help. Check the cords, then open a ticket.
  • Green light steady, nothing responds. The box is receiving power but has likely lost its configuration. This can happen when the jets stop mid bath. This is the case the reset is for, and it usually brings everything back at once.
  • Green light steady, only one massage is out. Check the pump cords before you reset. The second video on this page shows an Ultimate with three pumps, where the control box runs the air pump and one water pump, and the third pump with the inline heater needs its own power on a second line. If one massage is not working, a pump that is not plugged in is a common reason.

If every button is dead while the light is on, Why Do None of the Buttons Work Even Though the Tub Has Power? walks through the same decision in more detail.

The Control Box Reset, Step by Step

The first video on this page shows the whole procedure on the box. Work slowly, and label everything before you remove it. Putting each line back in the correct position matters as much as the reset.

  1. Disconnect the main power supply to the box. The green LED goes out when power is disconnected.
  2. Mark every connection. Label each air line and each electrical connection so it can go back in the same place.
  3. Disconnect all function connections from the box. Grasp each air tube firmly, then twist and pull carefully. Remove electrical connections slowly to avoid damaging any pins.
  4. Unplug the pumps. Disconnect the electrical connections to every air and water pump the tub has.
  5. Reconnect the main power supply. Watch for the green LED to come back on. It flashes four times and then stays solid green.
  6. Press and hold the config button. Locate the config switch on the control box and hold it down while the green LED cycles through its configuration process. It blinks once, then twice, then three times, then four times.
  7. Release at the blink count for your tub. In the video the button is released after the four-blink cycle. The LED then blinks four times, turns off and goes solid green. The count matches your tub's configuration, and the team can confirm the right count from your serial number.

When the LED is solid green again, the control box is reset and ready to be reconnected.

Reconnect and Test Every Function

Using your labels, reattach the air lines and the electrical lines to the box, and make sure each one is secured firmly. Then reconnect all the air and hydro pumps. If your tub has a digital keypad, reseat its plug at the display port with a firm push. A pad that stays dark with the green light on is covered in Why Isn't My Digital Control Pad Lighting Up?.

Fill the tub so the water is 1 to 2 inches above the highest jets, then test each function your tub has, one at a time: air, water, microbubbles and the LED lights. If the reset did not take, repeat the whole process once from the first step.

When to Stop and Open a Ticket

If the LED never goes solid, or the tub still does not respond after a second attempt, leave the breaker off and open a ticket at ellasbubbles.com/support or call (800) 480-6850. Include:

  • Your tub's serial number.
  • A photo of the control box showing the green LED and the connections.
  • The blink count you used when you released the config button.
  • A note on what happened just before the jets stopped, such as a storm, a GFCI trip or the jets cutting out mid bath.

If a breaker or GFCI will not hold at any point, leave the power off and have a licensed electrician look at the circuit before you try anything else.

Video
Watch: Ella's Bubbles: Control Box Reset with chapters and a full transcript.
Video

Watch: Proper Electrical Connections with chapters and a full transcript.

Common Questions

Is there a single reset button on an Ella walk-in tub?
No, there is no single reset button. A reset is a short sequence: switch the dedicated breaker off and back on, press Reset on the GFCI outlet, and confirm the green light on the blue control box is lit. If the light is on and the buttons still do nothing, the control box reset is the last step.
How do I know whether my control box needs a reset?
Look at the green power LED beside the power inlet on the blue control box. If it is steady green and none of the buttons respond, the box has likely lost its configuration and the reset is the right step. If the light is dark with a live outlet, the box or its cord is not passing power, and a reset will not help.
How many blinks should I wait for before releasing the config button?
In the reset video, the button is held while the LED blinks once, twice, three times and then four times, and it is released after that cycle. The count corresponds to your tub's configuration. The team can confirm the right count for your tub from its serial number.
Do I need to unplug the pumps before resetting the control box?
Yes. The procedure disconnects the main power, every air line and electrical connection on the box, and the electrical connections to all air and water pumps. Mark every connection before removal so each one goes back in the correct position.
What should I do if the control box reset does not work?
Repeat the whole process once. If the LED never goes solid green or the tub still does not respond, leave the breaker off and open a ticket at ellasbubbles.com/support with your serial number, a photo of the box and the blink count you used.
Why did my air jets turn on by themselves after my bath?
That is the auto purge, and it is normal. About 20 minutes after the air pump is switched off, it runs for 120 seconds to blow water out of the air lines. It cannot be stopped, and other features will not respond until it finishes.

About this guide. Answers in the Ella's Bubbles Ella's Bubbles Walk-In Tub Support Center are compiled from real conversations with owners, our technicians’ notes and the product documentation, then reviewed by our team. Models and options have evolved over the years, so a detail here may differ slightly from yours. If something looks different on yours, send us your serial number and a specialist will confirm it for your model.

Was this helpful?

Did this solve your question?

If not, open a ticket and our team will pick it up from here.