Support Center / Troubleshooting & Repairs / Why Do My Hydro Jets Switch From Low to High by Themselves?
Back to Troubleshooting & Repairs

Why Do My Hydro Jets Switch From Low to High by Themselves?

Ella hydro jets do not have low, medium and high settings, so they cannot step from one speed to another by themselves. One press turns the hydro pump on, the next press turns it off, and the strength you feel comes from the intensity dial, which mixes air into the water stream. When the massage seems to climb without being touched, the usual cause is the air massage system, and Why do my walk-in tub jet and blower motors stop and restart? covers the built-in restarts behind most of these reports.

Hydro Has One Speed, Air Has Three

It helps to separate the two systems, because the words low and high belong to only one of them.

  • Hydro massage is one press on and one press off. There is no speed button. The plain dial on the deck is the intensity dial, and it changes how much air is mixed into the water stream.
  • Air massage has three speeds on its push control. The first press is high, the second is medium, the third is low, and a fourth press turns the system off.

So if you are seeing a change from low to high, you are almost certainly watching the air system. The bubbles from the seat, the footwell floor and the bidet jets all belong to it. Bidet jets, for example, run at whatever air speed you have chosen and have no switch of their own.

The Auto Purge That Starts Without a Press

The most common reason the massage seems to come on strong by itself is the Auto Purge. On a tub with air massage, the blower starts automatically 20 minutes after the air pump is turned off and runs for 120 seconds to blow residual water out of the air lines. It is fully automatic, it cannot be stopped, and it is normal even if it starts while you are still in the tub.

Picture a typical bath. You run the air on low, switch it off, and stay in the water to soak. About 20 minutes later the blower starts with nobody touching a button, runs for two minutes and shuts off. From the seat, that can feel exactly like jets that went from low to high by themselves. If that is the pattern you see, once after the air was turned off and gone about two minutes later, nothing is wrong with the tub.

A Press You Did Not Mean to Make

The air button's order explains the other common report. The speeds run high, medium, low and then off, so the press after low turns the air off, and the next press starts it again at high. Every therapy has its own on and off control on the deck, and a hand, elbow, heel or towel that brushes the air button while you shift in the seat is enough to move it along. Two light brushes on a tub running at low will take it to off and then straight to high.

The control box also shuts the pumps off automatically after 20 minutes of continuous running, and starting the system again begins a new cycle. On the air side a fresh start is a first press, which is high. If the air stopped during a long soak and you restarted it, expect it to come back at high.

If a setting ever feels too strong and you want it off right away, How Do I Turn the Jets Off in an Emergency? lists every control. In short, press the hydro button once, and press the air button gently until it shuts off, which is three more presses from high. On a digital touchpad, hold the air icon for two seconds.

When the Hydro Stream Itself Feels Different

If the tub has no air massage, or you are sure it is the water jets that changed, three things decide how strong a hydro jet feels.

  1. The intensity dial. Turn it through its range with the hydro pump running. If turning the dial changes nothing at all, the air hose to the pump has most likely come off behind the access panel. Have your installer or a local licensed plumber open the panel and reconnect it firmly.
  2. The center nozzle of each jet. The center nozzle works as a valve that opens or closes that one jet. The video on this page shows a foot jet being adjusted this way. If the nozzle is too stiff to turn, the butterfly handles can be loosened with a pair of pliers. To be sure the valve is fully open, the half-cut opening inside the jet is lined up with the hole the water comes out of. The video finishes by tightening the nut so the nozzle does not turn, and a nozzle that is not secured that way can be moved.
  3. The water level. Hydro massage needs water 1 to 2 inches above the highest hydro jet before the pump runs. What Is the Water Line Before Running the Jets on a Walk-In Tub? gives the level for each therapy.

A light humming with nothing switched on is a separate matter. On a hydro massage tub that is the ozone generator running by itself, and it is normal. It is not a jet changing speed.

When to Open a Ticket

If the massage still changes without a press after you have ruled out the Auto Purge and a brushed button, or the dial and nozzles will not adjust the stream, open a ticket at ellasbubbles.com/support or call your Ella dealer or the team at (800) 480-6850. Include your serial number, which system was running, and what you found in the checks above. A photo of the blue control box with its cords and air tubes helps the team confirm the cause. Ella does not send technicians. Any part that is needed ships under the warranty, and a local licensed plumber or electrician does the labor.

Video

Watch: How to Adjust to Hydro Jets in Your Walk-In Tub? | Ella's Bubbles with chapters and a full transcript.

Video
Video

Common Questions

Do Ella hydro jets have low, medium and high speeds?
No. Hydro massage is one press on and one press off. The strength of the stream comes from the intensity dial, which mixes air into the water, and from the center nozzle on each jet.
Why did the bubbles start again after I turned them off?
That is the Auto Purge. On an air massage tub the blower starts by itself 20 minutes after the air pump is turned off and runs for 120 seconds to clear water from the air lines. It is normal and cannot be stopped.
Why does my air massage come back on at high speed?
The air button always begins at high. The first press is high, the second is medium, the third is low and the fourth turns it off, so any fresh start is high. A brushed button or a restart after the 20 minute shutoff will bring it back at high.
What if turning the intensity dial does not change anything?
The air hose to the pump has most likely come off behind the access panel. Have your installer or a local licensed plumber open the panel and reconnect it firmly. If the dial still does nothing, open a ticket with your serial number.
Can I adjust the pressure of just one hydro jet?
Yes. The center nozzle of each jet works as a valve, so turning it opens or closes that one jet. If it is too stiff to turn, the butterfly handles can be loosened with pliers, as the video shows.

About this guide. Answers in the Ella's Bubbles Ella's Bubbles Walk-In Tub Support Center are compiled from real conversations with owners, our technicians’ notes and the product documentation, then reviewed by our team. Models and options have evolved over the years, so a detail here may differ slightly from yours. If something looks different on yours, send us your serial number and a specialist will confirm it for your model.

Was this helpful?

Did this solve your question?

If not, open a ticket and our team will pick it up from here.