Ella hydro jets do not have low, medium and high settings, so they cannot step from one speed to another by themselves. One press turns the hydro pump on, the next press turns it off, and the strength you feel comes from the intensity dial, which mixes air into the water stream. When the massage seems to climb without being touched, the usual cause is the air massage system, and Why do my walk-in tub jet and blower motors stop and restart? covers the built-in restarts behind most of these reports.
Hydro Has One Speed, Air Has Three
It helps to separate the two systems, because the words low and high belong to only one of them.
- Hydro massage is one press on and one press off. There is no speed button. The plain dial on the deck is the intensity dial, and it changes how much air is mixed into the water stream.
- Air massage has three speeds on its push control. The first press is high, the second is medium, the third is low, and a fourth press turns the system off.
So if you are seeing a change from low to high, you are almost certainly watching the air system. The bubbles from the seat, the footwell floor and the bidet jets all belong to it. Bidet jets, for example, run at whatever air speed you have chosen and have no switch of their own.
The Auto Purge That Starts Without a Press
The most common reason the massage seems to come on strong by itself is the Auto Purge. On a tub with air massage, the blower starts automatically 20 minutes after the air pump is turned off and runs for 120 seconds to blow residual water out of the air lines. It is fully automatic, it cannot be stopped, and it is normal even if it starts while you are still in the tub.
Picture a typical bath. You run the air on low, switch it off, and stay in the water to soak. About 20 minutes later the blower starts with nobody touching a button, runs for two minutes and shuts off. From the seat, that can feel exactly like jets that went from low to high by themselves. If that is the pattern you see, once after the air was turned off and gone about two minutes later, nothing is wrong with the tub.
A Press You Did Not Mean to Make
The air button's order explains the other common report. The speeds run high, medium, low and then off, so the press after low turns the air off, and the next press starts it again at high. Every therapy has its own on and off control on the deck, and a hand, elbow, heel or towel that brushes the air button while you shift in the seat is enough to move it along. Two light brushes on a tub running at low will take it to off and then straight to high.
The control box also shuts the pumps off automatically after 20 minutes of continuous running, and starting the system again begins a new cycle. On the air side a fresh start is a first press, which is high. If the air stopped during a long soak and you restarted it, expect it to come back at high.
If a setting ever feels too strong and you want it off right away, How Do I Turn the Jets Off in an Emergency? lists every control. In short, press the hydro button once, and press the air button gently until it shuts off, which is three more presses from high. On a digital touchpad, hold the air icon for two seconds.
When the Hydro Stream Itself Feels Different
If the tub has no air massage, or you are sure it is the water jets that changed, three things decide how strong a hydro jet feels.
- The intensity dial. Turn it through its range with the hydro pump running. If turning the dial changes nothing at all, the air hose to the pump has most likely come off behind the access panel. Have your installer or a local licensed plumber open the panel and reconnect it firmly.
- The center nozzle of each jet. The center nozzle works as a valve that opens or closes that one jet. The video on this page shows a foot jet being adjusted this way. If the nozzle is too stiff to turn, the butterfly handles can be loosened with a pair of pliers. To be sure the valve is fully open, the half-cut opening inside the jet is lined up with the hole the water comes out of. The video finishes by tightening the nut so the nozzle does not turn, and a nozzle that is not secured that way can be moved.
- The water level. Hydro massage needs water 1 to 2 inches above the highest hydro jet before the pump runs. What Is the Water Line Before Running the Jets on a Walk-In Tub? gives the level for each therapy.
A light humming with nothing switched on is a separate matter. On a hydro massage tub that is the ozone generator running by itself, and it is normal. It is not a jet changing speed.
When to Open a Ticket
If the massage still changes without a press after you have ruled out the Auto Purge and a brushed button, or the dial and nozzles will not adjust the stream, open a ticket at ellasbubbles.com/support or call your Ella dealer or the team at (800) 480-6850. Include your serial number, which system was running, and what you found in the checks above. A photo of the blue control box with its cords and air tubes helps the team confirm the cause. Ella does not send technicians. Any part that is needed ships under the warranty, and a local licensed plumber or electrician does the labor.

Watch: How to Adjust to Hydro Jets in Your Walk-In Tub? | Ella's Bubbles with chapters and a full transcript.
Related Guides
- My walk-in tub turned on by itself: the air massage Auto-Purge is normal
- Why Does My Air Massage Stay on One Speed?
- Air jets will not shut off: which pump and button do I check?
Related Videos