Ella's Bubbles Walk In Tub Blog

Support Center / Sizes, Fit & Measuring / Will the Walk-In Tub Door Clear the Toilet?

Will the Walk-In Tub Door Clear the Toilet?

Whether the door will clear the toilet depends on your door family and on how tall and how close the toilet is. Inward-swing doors on the stainless steel, Ultra, Standard, Zen, Zen60, Flow and LayDown tubs open into the tub, so a toilet is never in their way. The outward U-shape door on the Capri, Monaco, Front Entry, Mobile, Lounger, ShaK and Big4One swings 165 degrees into the room, and the L-shape Transfer door opens 172 degrees with a cutout designed to pass over a standard-height toilet. Start by measuring from the hinge side of the planned door to the toilet, along with the toilet seat height.

Likely Causes

  • The toilet sits inside the swing envelope of an outward U-shape door, which needs roughly 20 to 21 inches of clear floor in front of the tub.
  • A tall comfort-height toilet: the L-shape Transfer door cutout sits about 20 to 21 inches above the floor, so it usually clears a 17 to 19 inch seat but not always a taller one.
  • The door side was chosen before the toilet position was checked; every model except the Front Entry comes left-hand or right-hand.

What to Check, in Order

  1. Identify your door family; inward doors need no floor space at all. Our guide to inward versus outward swing doors lists every model.
  2. Measure the toilet: seat height, how far it projects from the wall, and its distance from where the tub door will begin.
  3. For an outward U-shape door, draw a half circle on the floor from the hinge side, with a radius equal to the door width; the Monaco and Mobile drawings print a 19 1/4 inch opening. See planning floor space for the outward-swing door.
  4. For a Transfer tub, budget the tub width plus about 36 inches beside the tub, and confirm the toilet sits below the cutout and far enough from the hinge side for the lower section of the L to swing past. Widths and arcs are in door opening widths and swing arcs by model.
  5. Note where the door begins along the tub. On the Lounger, for example, the U-shape door begins about 28 3/4 inches from the end, so a toilet that projects about 28 inches from the same wall may never reach the swing.
  6. If the numbers are tight, consider the Front Entry, whose door is at the end of the tub, or an inward-swing model such as a stainless steel door tub, the Standard, the Zen or the Zen60.
  7. For a corner install, keep the door end open and put the long back side, which has no finished cover, against the wall. See bathroom layout planning.

When to Open a Ticket

If the toilet is close to the planned door, send a sketch with the toilet seat height, its distance from the wall and from the tub, and the model and door side you have in mind, through ellasbubbles.com/support. Your Ella dealer or the team at (800) 480-6850 will confirm the fit from your measurements.

The video walks through the five Ella door styles, noting that outward doors need about 20 inches of swing clearance and that the L-shape Transfer door fits over a standard toilet with 36 1/2 inches of clearance.

Common Questions

How much room does the outward door need in front of the tub?
The outward U-shape door swings 165 degrees, and our door videos describe about 20 to 21 inches of clearance in front of the tub. Keep a half circle of roughly the door width clear on the floor from the hinge side.
Will the door swing over a chair height toilet?
The L-shape Transfer door cutout sits about 20 to 21 inches above the floor, so a tall comfort-height toilet can be a problem. Outward U-shape doors have been installed swinging over a toilet, but only after measuring.
Which models work if the toilet sticks out 28 inches from the wall?
Where the toilet sits relative to the door opening matters more than its length. Short of where the door begins, the door may clear it; directly in front of the door, choose the Front Entry or an inward-swing model. The team confirms from your sketch.
Which end should stay accessible in a corner install?
The door end must stay open for entry and, on an outward door, for the swing arc. The front and one end come finished from the factory, so only the long back side goes against a wall.

Did this solve it?

If not, open a ticket and our team will pick it up from here.

Open a Support Ticket