Support Center / Troubleshooting & Repairs / Why Does the Foot Massage on My New Walk-In Tub Do Nothing?
Back to Troubleshooting & Repairs

Why Does the Foot Massage on My New Walk-In Tub Do Nothing?

On a walk-in tub with independent foot massage, the foot jets run off their own pump, and that pump is usually on a separate circuit from the seat jets, so the rest of the tub can work perfectly while the foot side has no power at all. On a newly installed tub the most common cause is a tripped GFCI or breaker on the foot massage circuit, followed by a pump cord or a small control hose that is not fully seated. The general method is in One Push Button Does Nothing While the Others Work: The Breaker Check and the Hose Swap Test, and this page applies it to the two things owners ask about most after an installation: a foot massage that does nothing and a light that stays dark.

Why the Foot Jets Can Be Dead While Everything Else Works

Independent foot massage means a second pump feeds the foot and calf jets, separate from the pump that feeds the seat jets. That is why a tub set up this way carries a second intensity dial on the deck, so the seat jets and the foot jets can be set separately. The Ella Ultimate includes independent foot massage as standard, and the Ella Capri offers it as an option.

Two details about this layout explain almost every new tub report:

  • The pumps are not all on the same circuit. The foot massage pump is on a separate breaker from the other pumps. One tripped GFCI can leave the foot jets dead while the water, the air jets and the light all work normally.
  • The push buttons are pneumatic. Pressing a button sends a puff of air down a small hose to the blue control box under the seat, and the box switches the pump or the light. A button can be perfectly good while its hose has slipped off a port.

So when one function does nothing, the fault is in one of three places: that function's circuit, the air hose between the button and the control box, or the pump and its plug. The checks below go through them in that order, starting with the ones that need no tools.

What to Check First, in Order

  1. Fill the tub above the highest jets. A water pump must never run dry, and a pump that has been run dry is damaged permanently. Have the water above the highest jets before you press the foot button or test anything.
  2. Reset the GFCI outlet and the breaker for the foot massage circuit. A tripped circuit here is the most common reason the back jets run and the foot jets do nothing. Do this before you open any panel.
  3. Press the foot button and listen. If you hear a click but nothing runs, the control is sending its signal, and the problem is on the pump's power side rather than the button.
  4. Listen for the pump and try the foot dial. The intensity dial adds or removes air in the jet stream and never changes the speed of the pump. Turned all the way down, it leaves the jets barely perceptible while the pump keeps running. If you can hear the foot pump but feel nothing, turn the foot dial up. If the pump runs and the dial changes nothing, check that the air hose is still connected at the pump. What Is the Intensity Control Dial on a Walk-In Tub? explains how the dial works.
  5. Open the access panel and check the foot pump's cord. The large access panel is held on by magnets, so a butter knife slipped behind the edge will pry it loose. Confirm the foot pump's power cord is plugged fully into its receptacle and is undamaged.

The Hose Swap Test for the Foot Button

If the circuit is live and the cord is seated, the hose swap test tells the button side from the pump side. Find the blue control box screwed to the frame. It has three 3/8 inch air hoses and three power plugs coming out of it, and a green LED. The white face of the box carries the port labels: Airswitch Pump #1 is the water button, Blower/Airswitch Pump #2 is the air button, and Light Airswitch is the light button.

  1. Pull the hose off the port for the dead button, and pull the hose off the Light Airswitch port.
  2. Plug each hose into the other port.
  3. Press the light button. It should now start the pump that belongs to the dead button.
  4. Press the dead button. It should now turn on the LED light.
  5. Return both hoses to their original ports.

If the water pump starts during the test and the tub is not filled above the jets, press the button again immediately to stop it. The air pump can run dry safely, but the water pump cannot.

The results read this way:

  • The light button runs the pump, but the dead button does not light the LED. The problem is on the button side: the button itself or the hose between the button and the box.
  • The dead button lights the LED, but the light button does not start the pump. The button and hose are fine. The problem is the pump, its plug into the box, or the box.

If It Is the Light That Does Not Work

A dark light on a new tub gets its own short list, because the LED has its own control box and transformer, separate from the pump circuits. Jets that run perfectly do not prove the light circuit is powered.

  • Start with the button. Pressing and holding the light button for two seconds turns the light off. Press it once and watch for the color cycle, to be sure the light was not simply switched off.
  • Check the power connector. Behind the access panel, confirm that the three prong power connector on the back of the chromatherapy box is plugged in firmly.
  • Listen for the relay. A click when the button is pressed tells you the signal is arriving.
  • Check the hose. On tubs with push controls the light button is pneumatic, and its thin hose plugs into the bottom port labeled Light Airswitch on the control box. Make sure the hose is seated at both ends.
  • Swap to confirm. Swap the light hose with the air button's hose at the box and press the other button. That shows whether the button and hose or the box is at fault.

What Is Normal, and When to Contact the Team

A tub with independent foot massage runs two pumps together, so a steady hum that is louder than a single pump is expected, and so is the relay click when you press a button. Rattling, a loud bang or a burning smell is different: switch the tub off at the breaker and leave it off until it has been checked. Why Does My Walk-In Tub Make a Buzzing or Hissing Noise? sorts the normal sounds from the ones that need attention.

If the circuit and the cord are good and the foot massage still does nothing, open a ticket at ellasbubbles.com/support or call (800) 480-6850. Send your model and serial number, photos of the control box and wiring, and the result of each check above, including whether you heard a click and what the hose swap test showed. Technical support then decides whether a part needs adjusting or replacing. Ella does not send technicians. Replacement parts ship under the warranty, and a local licensed plumber or electrician does the labor.

Video

Common Questions

Why do the seat jets work when the foot jets do nothing?
On a tub with independent foot massage, the foot jets run off their own pump, and that pump is on a separate breaker from the other pumps. A single tripped GFCI can leave the foot side without power while everything else works. Reset the GFCI outlet and the breaker for the foot massage circuit first.
What does a click with no foot jets tell me?
A click when you press the foot button means the control is sending its signal. The problem is then on the pump's power side rather than the button. Check the circuit, then confirm the foot pump's power cord is plugged fully into its receptacle and is undamaged.
Can the foot intensity dial make the foot jets seem off?
Yes, it can. Turning the dial all the way down leaves the jets barely perceptible while the pump keeps running, because the dial only adds or removes air in the jet stream. If you hear the foot pump running, turn the foot dial up before you test anything else.
Is it safe to run the hose swap test on an empty tub?
Fill the tub above the highest jets before you begin, because the water pump must never run dry. If a water pump starts during the test and the tub is not filled, press the button again immediately to stop it. The air pump can run dry safely.
Why is the light on my new walk-in tub not coming on?
First press the light button once and watch for the color cycle, since holding the button for two seconds turns the light off. The LED has its own control box and transformer, so check that the three prong power connector on the back of the chromatherapy box is plugged in firmly. Then confirm the thin hose is seated in the Light Airswitch port.
Who repairs the foot massage if a part has failed?
Ella does not send technicians. After technical support reviews your photos and serial number, the replacement part ships under the warranty and a local licensed plumber or electrician does the labor. Start at ellasbubbles.com/support or (800) 480-6850.

About this guide. Answers in the Ella's Bubbles Ella's Bubbles Walk-In Tub Support Center are compiled from real conversations with owners, our technicians’ notes and the product documentation, then reviewed by our team. Models and options have evolved over the years, so a detail here may differ slightly from yours. If something looks different on yours, send us your serial number and a specialist will confirm it for your model.

Was this helpful?

Did this solve your question?

If not, open a ticket and our team will pick it up from here.

Open a Support Ticket