If your foot jets stopped working while the upper jets, air and light still run, the most likely cause on an Independent Foot package is a tripped circuit or GFCI feeding the second pump, and the first thing to check is that outlet. Independent foot massage runs on its own pump, its own button and its own circuit, so the seat jets can be perfect while the foot and calf jets sit silent. That is also why the foot massage button often stops working after a power outage: the foot pump's GFCI tripped and was never reset. On a single hydro pump tub the foot jets are part of the main system and there is no separate circuit to check. Independent foot massage explains which tubs have the second pump.
Likely Causes
- The GFCI outlet or breaker for the foot pump circuit has tripped.
- The air hose from the foot massage button has come loose or holds a trapped pulse of air.
- The relay for the foot pump is not passing power, or the pump itself has a fault.
- The foot intensity dial is turned all the way down, or its air hose is off.
- A single foot jet is blocked with debris rather than the pump being at fault.
What to Check, in Order
- Reset the GFCI outlet and breaker for the foot pump. Tubs with independent foot massage often have more than one dedicated line, so look for a second outlet or breaker, including one behind the access panel.
- Fill above the calf jets before testing; the pump must never run dry, and water level before running the jets shows the level.
- Check the button hose at the control box and at the button, pushing it firmly onto each nipple. Press the button and listen for the relay click.
- If there is no click, burp the line as the video shows: disconnect the air tube at the relay, let it relieve, and reconnect it.
- If the relay clicks but the pump does not start, check the pump's connection at the control box; that pattern points to the pump or its power feed rather than the button.
- If the pump runs but one jet is weak or not blowing water, turn the foot intensity dial up, confirm its air hose is attached, then run the monthly vinegar flush. The order is always button, air hose, relay, pump, dial. Pump not working troubleshooting has the full sequence.
The video shows the pneumatic relay that powers the pump, explains that compressed air trapped in the button tube stops the signal from reaching it, and disconnects the tube at the relay to let it relieve before reconnecting.
When to Open a Ticket
If the GFCI holds, the hose is secure and the relay clicks with no pump response, contact your Ella dealer or the team at (800) 480-6850, or open a ticket at ellasbubbles.com/support. Include your serial number, your therapy package, a photo of the foot pump and its control box, and whether the other therapies still run. The foot pump and its controls are covered under the Lifetime Limited Warranty on supporting equipment.