What electrical circuit does an Ella walk-in tub need, 15, 20 or 40 amp?

Updated November 2026

An Ella walk-in tub with pumps runs on dedicated 20 amp, 120 volt GFCI protected circuits, one for every labeled power cord on the tub, and its control boxes are marked to connect only to a branch circuit with overcurrent protection rated 20 amps or less, so a 40 amp circuit is not what the tub is wired for and should not feed it. The published 15 amp cases are narrow: the Flow's spec sheet calls for one dedicated 15 amp GFCI line, and a soaking tub whose only electrical item is the heated seat and back is drawn at 15 amps because it has no pumps. How Many GFCI Circuits Does My Walk-In Tub Need? gives the line count rule for the whole line; this page sorts the 15, 20 and 40 amp question by package, explains what a heated seat does to the count, and defines the double drain that comes up in the same conversation with an electrician and a plumber.

15, 20 or 40 Amps, by Package

The circuit requirement follows the therapy package rather than the model name, because the pumps and heaters are what draw the current. Every cord on the tub carries a factory label, and on a two line tub the stickers read Line 1 20 Amp and Line 2 20 Amp. The table collects the published line counts and ratings.

PackageDedicated linesCircuit ratingWhat it means for your electrician
Soaking tub, no pumps, no heated seatNoneNo outlet requiredThe drains are gravity driven, so there is nothing to plug in
Soaking tub with heated seat and back only115 amp, 120 voltHeater pads only; the one package drawn at 15 amps on the schematic
Ella Flow, as published on its spec sheet115 amp GFCIThe one model with a published 15 amp line
Hydro only, air only, or hydro plus air120 amp, 120 volt GFCIThe usual single line tub
Air plus hydro plus heated seat and back220 amp, 120 volt GFCI eachAdding the heated seat moves a one line tub to two lines
Hydro plus microbubble, or hydro plus independent foot massage220 amp, 120 volt GFCI eachA second pump means a second line
Air, hydro, hydro foot, microbubble, heated seat and back (Transfer60, TransferXXL, Ultimate)220 amp, 120 volt GFCI eachThe fullest single seat stack still runs on two lines
ShaK or Big4One with all four therapies; two seat tubs with the full package320 amp, 120 volt GFCI eachThe only diagrams that show three wall outlets

What the differences mean: 20 amps at 120 volts is the published standard for every Ella tub with a pump, and the count of lines, not the rating, is what changes from package to package. Fifteen amps appears only where there is no pump at all or on the Flow's own spec sheet; the GFCI article notes a 15 amp line can work on some lighter packages, but 20 is what Ella publishes, so plan 20. A 40 amp circuit appears nowhere in the published requirements. What people describe as a whirlpool is the hydro massage system on an Ella spec sheet, and its pump runs on the same 20 amp line as any other Ella pump; the ShaK's spec sheet, for example, lists a 9 amp 900 watt seat hydro pump, a 7 amp 900 watt foot pump, a 6 amp 650 watt in-line heater and a 4.5 amp 500 watt air pump, which is why those loads are split across separate 20 amp lines rather than fed from one large breaker. If a 40 amp breaker is already in the room from a previous spa, it is not what should feed an Ella tub.

Does a Heated Seat Change the Circuit?

The heated seat and backrest does not take a circuit of its own. Its surface heater pads are fed from the master control box, the blue box by the motor that also runs the air pump, water pump and LED from labeled ports. What the heated seat changes is the line count: an air plus hydro tub that runs on one line moves to two dedicated 20 amp lines once the heated seat is added, which is why the heated seat variants sit in the two line group in the GFCI article. The only time the heated seat sets the rating rather than the count is on a soaking tub with no pumps, where the schematic calls out 15 amp, 120 volt because the heater pads are the only load. What the Full Push-Control Package Schematic Shows walks through how the heated seat is powered inside the fullest package, and the digital controller version of the same package is explained in What the Full Digital Controller Package Schematic Shows; both run on two dedicated 20 amp lines.

Why 15 Amp Receptacles Cause Trouble on a 20 Amp Tub

Some master control boxes carry a true 20 amp plug with one blade turned sideways, and that plug will not fit a 15 amp receptacle. Installers meet this when only the microbubble runs because its cord was the only one that fit; the fix is a 20 amp receptacle, not an adapter. A few other rules save a call on install day. Two labeled cords must never share one GFCI, because the breaker trips as soon as the second pump starts. One GFCI, at the breaker or at the receptacle, is sufficient, so there is no need to double up protection. The outlets belong under the seat area, inside or directly behind the equipment compartment, so every pump and heater cord reaches without an extension cord, and other appliances stay at least 3 feet from the tub. A three pump tub has more cords than control box ports because the third pump is powered with the in-line heater on its own line. Which Cord Plugs In Where on My Walk-In Tub? matches each labeled cord to its box and outlet.

What a Double Drain Is

The double drain is Ella's 2 inch T-type dual port floor drain, fitted on the tubs that use it: two independent 2 inch drains with four 2 inch ports in total, so the drain pipe can be installed in either direction and the house drain can connect to either port or to both. Two end caps are included to close any ports that go unused. For your plumber it means the drain line can come from whichever side suits the room, and a Y fitting into the house drain is preferred over a T. It is a plumbing term, not an electrical one, but it comes up in the same planning conversation because the drain end and the outlet location are both fixed by the model and door hand before the floor is closed.

What to Give Your Electrician Before Rough-In

Count the labeled cords on the tub, or read the package sheet packed with it; each cord equals one dedicated 20 amp, 120 volt GFCI circuit. The tub cannot share a circuit with any other appliance, and the breaker panel must use GFCI protected breakers, with the amperage set by the number and type of components in your package. The video below shows where Ella publishes the electrical requirements for each jetting package, including how many plugs and how many lines a given tub needs. If you would rather have it in hand, the team can email the electrical diagram for your model and package so your electrician has the line count and outlet location before rough-in; reach them through ellasbubbles.com/support or at (800) 480-6850. For the one single seat model that reaches three lines, What electrical circuits does the Ella ShaK need for all four therapies? lists every pump and its published amperage.

Video
Chapters in this video
  1. 0:00 Electrical Components Clearly Marked The video explains the electrical requirements for installing an Ella's Bubbles walk-in tub, showing how components are clearly marked and accessible.
  2. 0:31 Dedicated GFCI Protected Outlets The contractor connects the tub to the home's power supply, emphasizing the need for dedicated GFCI protected outlets and breakers.
  3. 0:57 Finding Electrical Requirements Online The video directs viewers to the Ella's Bubbles website to find detailed electrical requirements based on their specific tub model and jetting packages.
  4. 1:28 Plug In and Enjoy After proper installation, the tub is ready to be plugged in, and technical support is available for any questions.

Watch: Ella's Bubbles: Proper Electrical Installation For Your Walk-In Tub with chapters and a full transcript.

Video
Chapters in this video
  1. 0:00 Electrical Components Are Marked Ella's Bubbles ensures all electrical components are clearly marked and easily accessible for installation.
  2. 0:13 Dedicated GFCI Protected Outlets Your contractor connects the tub to your home's power supply using dedicated GFCI protected outlets.
  3. 0:25 GFCI Protected Breakers The breaker box must utilize GFCI protected breakers with the appropriate amperage value for your tub's components.
  4. 0:40 Enjoy Your Walk-In Tub Proper installation provides years of reliable, trouble-free walk-in tub enjoyment.
Video
Chapters in this video
  1. 0:00 Troubleshooting Massager Malfunctions The technician explains that a common problem with massagers not working is an unplugged pump or component.
  2. 0:27 Checking Pump Power Connections The technician advises checking the pump and its power cord to ensure it is properly powered up.
  3. 0:42 Verifying Control Box Power The technician shows how to check the control box for a green light indicator, which means power is flowing to it.

Common Questions

Can I run my walk-in tub on a 15 amp circuit?
The published standard for any Ella tub with a pump is a dedicated 20 amp, 120 volt GFCI circuit per labeled cord. The exceptions are the Flow, whose spec sheet calls for one 15 amp line, and a soaking tub with only a heated seat and back. Some master control boxes also carry a 20 amp plug that will not fit a 15 amp receptacle, so plan 20 amp receptacles.
Is a 40 amp breaker enough for a walk-in tub with jets?
A 40 amp circuit is not what Ella tubs are wired for. The control boxes are marked for a branch circuit with overcurrent protection rated 20 amps or less, so your electrician should run dedicated 20 amp, 120 volt GFCI lines, one per labeled cord, rather than feed the tub from a 40 amp breaker.
Does a heated seat need its own electrical circuit?
No. The heater pads are fed from the master control box, not from a separate cord. It does change the count, though: an air plus hydro tub that runs on one line needs two dedicated 20 amp lines once the heated seat is added. On a soaking tub with no pumps, the heated seat alone is drawn at 15 amps.
Why does my walk-in tub have two or three power cords?
Each labeled cord is one dedicated 20 amp GFCI circuit, and the count follows the therapy package. Hydro, air or hydro plus air is one cord; adding microbubble, independent foot massage or a heated seat makes two; the ShaK, Big4One and two seat full packages have three. No two cords may share one receptacle.
What is a double drain on a walk-in tub?
It is Ella's 2 inch T-type dual port floor drain: two independent 2 inch drains with four 2 inch ports, so the drain line can run in either direction and connect to either port or both. Two end caps close the unused ports, and a Y fitting into the house drain is preferred over a T.
Can two tub cords share one GFCI outlet?
No. Each labeled cord needs its own dedicated 20 amp, 120 volt GFCI circuit shared with nothing else, and two cords on one circuit trip the breaker as soon as the second pump starts. One GFCI, at the breaker or at the receptacle, is sufficient for each line.

About this guide. Answers in the Ella’s Bubbles Support Center are compiled from real conversations with tub owners, our technicians’ notes and the product documentation, then reviewed by our team. Tub models and options have evolved over the years, so a detail here may differ slightly from your exact tub. If something looks different on yours, send us your serial number and a specialist will confirm it for your model.