Support Center / Plumbing & Electrical / What are the air system's electrical requirements, and is a plug-in GFCI acceptable?
Back to Plumbing & Electrical

What are the air system's electrical requirements, and is a plug-in GFCI acceptable?

An Ella air massage package calls for one wall outlet that is GFCI protected on a dedicated line, 20 amp and 120 volts, feeding a variable speed air pump rated 110 to 120 volts at 4.5 amps. A plug-in GFCI receptacle is acceptable, because the protection can sit at the receptacle or at the breaker, and one or the other is sufficient. The rule for every package is in How Many GFCI Circuits Does My Walk-In Tub Need?, and this page gathers everything that applies to the air system so your electrician can plan the rough-in with confidence.

The Air System Requirement in Plain Terms

Ella walk-in tubs are plug-in, never hardwired. Every pump runs on ordinary 120 volt household power, there is no 240 volt wiring, and each electrical line on the tub ends in a standard three-prong plug. For a tub with air massage only, the published requirement comes down to a short list:

  • One wall outlet. The air massage package is drawn with a single outlet feeding the variable speed air pump.
  • 20 amp, 120 volts. This is the published standard for every Ella tub with a pump. A 15 amp line can work on some lighter packages, but 20 is the published standard.
  • GFCI protected. Every line on the tub must be GFCI protected.
  • Dedicated. The tub cannot share a circuit with any other appliance.
  • Pump rating. The variable speed air pump is rated 110 to 120 volts at 4.5 amps.
  • Licensed installation. The line should be installed and tested by a licensed electrician, and extension cords must never be used to power the unit.

The control boxes on the tub are marked to connect only to a branch circuit with overcurrent protection rated 20 amps or less, so a larger circuit is not what the tub is wired for. What electrical circuit does an Ella walk-in tub need, 15, 20 or 40 amp? sorts that question package by package.

Is a Plug-In GFCI Receptacle Acceptable?

Yes. Your electrician can put the GFCI protection at the breaker or at the receptacle, and one or the other is sufficient. Doubling up the protection is not needed, and it is listed among the common causes of confusion when owners troubleshoot a tub circuit.

Ella's guidance actually favors the receptacle. A GFCI receptacle placed in or behind the equipment compartment under the seat can be reset through the access panel instead of at the panel board, which is a real convenience for the person using the tub. Many installers place the GFCI at that outlet for exactly this reason.

One detail to check before the receptacle is bought: some master control boxes carry a 20 amp plug with one blade turned sideways. That plug needs the matching 20 amp receptacle, since a standard 15 amp receptacle will not accept it. Have your electrician look at the plug on your tub, or ask the team for the electrical diagram for your model, before the outlet goes in.

Where the Outlet Should Go

The best place for the outlet is under the seat area, inside or directly behind the equipment compartment, so the factory cord reaches without an extension. A few placement rules travel with it:

  • Keep other appliances at least 3 feet from the tub.
  • Leave the equipment compartment uninsulated.
  • Make sure the outlet can be reached through the access panel if it is the GFCI device, so it can be reset easily.

Where to Put the Outlet: Seat-Side Placement, Cord Reach, the 20 Amp Receptacle, GFCI Under the Tub, and the Three Foot Rule covers the placement in full.

When the Air System Is Combined with Other Therapies

The package, not the model name, sets how many dedicated lines a tub needs. Air massage on its own is one line, and it stays at one line when hydro massage is added on a single-seat tub. The count changes when a second hydro pump or the heated seat joins the package. The table shows the published counts for the packages that include air.

Package that includes airDedicated 20 amp, 120 volt GFCI linesWhat it means for the rough-in
Air massage1One outlet feeding the variable speed air pump, rated 110 to 120 volts at 4.5 amps
Air + Hydro, single-seat tub1One outlet still covers both systems
Air + Hydro + heated seat and back2Adding the heated seat moves a one line tub to two lines
Air + Hydro + Hydro Foot, push controls2The schematic shows two wall outlets for the Royal, Monaco, Elite, Capri, Shak, Transfer60, Transfer32 and TransferXXL
Air + Hydro + Hydro Foot + Microbubble, with or without heated seat and back2The Transfer60, TransferXXL and Ultimate stay at two lines even fully loaded
Digital full package3Listed only for the Shak and the Big4One

What the differences mean: if your tub has air massage alone, or air plus hydro on a single-seat tub, plan for one new dedicated circuit from your panel. The step to two lines happens when independent foot massage brings a second hydro pump or when the heated seat and back are added, as Which tubs with independent foot massage run on one dedicated circuit? explains. As one example, air plus hydro on the Front Entry is shown with one outlet, while hydro plus independent foot massage is shown with two. Each line needs its own circuit, because two labeled cords on one circuit trip the breaker as soon as the second pump starts. Confirm the outlet count for your exact model and package before rough-in.

How to Confirm the Count for Your Own Tub

Ella labels the electrical lines at the production facility, so the simplest check is to count the labeled cords on the tub or read the package sheet packed with it. Each labeled cord equals one dedicated 20 amp GFCI circuit. The count is also listed under the jetting packages tab of the comparison chart on ellasbubbles.com and on your model's spec sheet.

The video on this page is a good one to share with your electrician. It shows that the electrical components are clearly marked and easily accessible, states that dedicated GFCI protected outlets must be used and that the tub cannot share a circuit with any other appliance, and points to where the number of plugs and lines for each tub is published. The team can also email the electrical diagram for your model, so your electrician has the count and the outlet location before the walls are closed. You can reach the team at ellasbubbles.com/support or (800) 480-6850.

What Is Normal Once the Air System Is Plugged in

Two behaviors of the air system are worth knowing so they are not mistaken for an electrical fault. First, on Ella three-speed air massage push controls, the first press is high speed, the second press is medium, the third press is low, and a fourth press turns the system off. Second, the Auto Purge activates automatically 20 minutes after the air pump is turned off and runs for 120 seconds to blow residual water out of the air lines. It is fully automatic and cannot be stopped, so an air pump that starts on its own shortly after your bath is working exactly as designed.

Video

Watch: Ella's Bubbles: Proper Electrical Installation For Your Walk-In Tub with chapters and a full transcript.

Video

Common Questions

Can the GFCI protection be at the breaker instead?
Yes, the protection can be at the breaker or at the receptacle, and one or the other is sufficient. Ella's guidance favors a GFCI receptacle in or behind the equipment compartment under the seat, because it can be reset through the access panel. Your licensed electrician can choose the arrangement that suits your home.
Does the air system need a 20 amp receptacle?
The published requirement is a dedicated 20 amp, 120 volt GFCI protected line. If the master control box on your tub carries the 20 amp plug with one blade turned sideways, the receptacle has to be the matching 20 amp type. A standard 15 amp receptacle will not accept that plug.
Can the air pump share a circuit with another appliance?
No, the line must be dedicated with nothing else on it. The tub cannot share a circuit with any other appliance, and other appliances should be kept at least 3 feet from the tub. Extension cords must never be used to power the unit.
How many outlets does an air plus hydro tub need?
Air plus hydro on a single-seat tub runs on one dedicated 20 amp, 120 volt GFCI line. The count moves to two lines when independent foot massage, microbubble or the heated seat and back are added. Count the labeled cords on your tub to confirm, because each one needs its own circuit.
Is the air system hardwired to the house wiring?
No, Ella walk-in tubs are plug-in and never hardwired. Each electrical line ends in a standard three-prong plug and runs on 120 volt household power. There is no 240 volt wiring.
Why does the air pump start after my bath?
That is the Auto Purge, which activates automatically 20 minutes after the air pump is turned off. It runs for 120 seconds to blow residual water out of the air lines. It is fully automatic, cannot be stopped, and is normal.

About this guide. Answers in the Ella's Bubbles Ella's Bubbles Walk-In Tub Support Center are compiled from real conversations with owners, our technicians’ notes and the product documentation, then reviewed by our team. Models and options have evolved over the years, so a detail here may differ slightly from yours. If something looks different on yours, send us your serial number and a specialist will confirm it for your model.

Was this helpful?

Did this solve your question?

If not, open a ticket and our team will pick it up from here.