The unions at the hydro pump and the in-line heater on an Ella walk-in tub are nominal 2 inch PVC. We do not publish a replacement union nut part number, so the team confirms the right part from your model, your serial number and a photo of the union. If a drip is the reason you are asking, the nut is rarely the problem: How Do I Fix a Leaking Union Gasket at the Pump or Heater? gives the re-seat routine that solves most union leaks without any new part.
The Size, and Why the Part Is Confirmed by Photo
The in-line heater is part of the hydro massage system. It is plumbed in line with the hydro pump, and unions join it to the pipework so the joints can be undone and remade. Those unions are nominal 2 inch PVC, the same as the unions at the hydro pump.
A replacement part number for the union nut is not listed here, and that is deliberate. The serial number tells the team when the tub was made and which replacement parts are compatible with it, so the right part is matched to your tub instead of guessed from a general list. To have the part confirmed, open a ticket at ellasbubbles.com/support or call (800) 480-6850 with:
- Your model.
- Your serial number. The serial label is behind the magnetic access panel next to the door.
- A clear photo of the union, showing the nut and the fitting on each side of it.
The serial number video on this page shows where that label sits, on the inside of one of the removable panels, and explains that it lets the team see when the tub was made and which replacement parts are compatible. The in-line heater video shows what the heater does: when you engage the hydro massage, the heater works with the water pump to maintain a consistent warm temperature.
The Joints Under the Tub, Side by Side
Several threaded connections sit close together under a walk-in tub, and people use the words union and nut for more than one of them. This table sorts them by size and by what actually seals each one, using only the figures in Ella's guides.
| Joint | Size | What seals it | What it means for a repair |
|---|---|---|---|
| Union at the in-line heater | Nominal 2 inch PVC | O-ring | Take apart, re-seat the O-ring, reassemble snug by hand; check that the heater threads match the pipe threads |
| Union at the hydro pump | Nominal 2 inch PVC | O-ring | Take apart, re-seat the O-ring, reassemble snug by hand |
| Drain union nut, PVC elbow to brass drain | 2 inch drain; standard 2 inch PVC fittings work under an Ella tub | Rubber gasket with two faces, only one seals | Flip the gasket so the sealing face sits against the brass, then hand tighten only |
| Plug on the hydro return elbow | not listed | 100 percent silicone | The one spot under the tub where silicone belongs |
What the differences mean for you: the heater and pump unions share the same nominal size and the same sealing method, so the same repair applies to both. The drain union looks similar but seals on a two-faced rubber gasket, not an O-ring, and Where Do the Extra Rubber Gaskets in My Tub Parts Box Go? shows where those gaskets belong. None of these joints seal on their threads, which is why Should I use thread tape or sealant on walk-in tub drain and union fittings? explains that Ella's repair guides do not call for tape or pipe sealant at the unions.
If a Drip Is Why You Are Asking
Most people who look up a union nut size have a union that weeps. A union at the pump or heater that keeps dripping after it has been tightened almost always has an over-tightened or displaced O-ring. No amount of extra force will make a displaced O-ring seal, and the water finds the gap beside it every time the pump runs. A new nut does not change that, and in most cases nothing has to be replaced.
The published fix is short:
- Switch the pumps off and dry the union.
- Take the union apart.
- Re-seat the O-ring squarely in its groove.
- Reassemble the union snugly by hand instead of continuing to turn the nut.
- Run the hydro pump and watch the joint with a flashlight.
At the heater, also check that the heater threads match the pipe threads before you reassemble. Over-tightening is what pushes the O-ring out of place, so snug by hand is the goal. Never start a pump until the tub is filled.
Confirm the Heater Union Really Is the Source
Water that collects under the tub can come from several connections, so isolate the source before you open anything. Open the access panel, dry the whole cavity, and lay dry paper towels under the pump, the heater, the drain fittings and the faucet connections. Fill the tub with the pumps off and wait. If a towel gets wet now, the water is not coming from a union. Then run the hydro pump alone for several minutes and look at the unions at the pump and at the heater with a flashlight. Water that shows only while the jets run usually comes from a union at the pump or heater, not the drain.
The unions are also the joints most likely to shift in transit, because shipping vibration can loosen unions and air lines. That is why every Ella tub gets a fill test before the walls close, and why Ella's pre-installation guidance calls a union drip found during that test a normal install-stage adjustment, not a defect. The warranty activation form's pump check runs the hydro system for at least 20 minutes while every connection is confirmed watertight, as Does the In-Line Water Heater Need Checking for the Warranty Activation Checklist? describes.
If a Part Does Turn Out to Be Faulty
If the nut, the union or the heater fitting is cracked or damaged, stop tightening and photograph it. Send the photo with your model and serial number through ellasbubbles.com/support or call (800) 480-6850. Once the team has verified the problem, the part ships under the parts warranty, and your local licensed plumber does the labor. Ella's Bubbles does not send technicians, so it helps to have your plumber's visit planned around the part's arrival.