Support Center / Plumbing & Electrical / Does the heated seat need its own circuit, and can it be 15 amp?
Back to Plumbing & Electrical

Does the heated seat need its own circuit, and can it be 15 amp?

Updated September 2026

No. The heated seat and backrest on an Ella walk-in tub is powered through the master control box, the blue box beside the motor, from a labeled port, so it never gets a wall circuit to itself. What it does change is the published line count: an air plus hydro tub needs one dedicated 20 amp, 120 volt GFCI protected circuit, and adding a heated seat moves the tub to two, as How Many GFCI Circuits Does My Walk-In Tub Need? explains. A 15 amp line can work on some lighter packages, but 20 amps is the published standard, and the 20 amp plug on some master control boxes will not fit a 15 amp receptacle at all.

Where the Heated Seat Gets Its Power

Every pump, heater and control box on an Ella walk-in tub is labeled at the factory, and the heated seat is not a separate appliance with its own cord to the wall. Its surface heater pads plug into the master control box, and the surface key pad, the push button that switches the heat on, connects to the same box. The master control box takes power at a single inlet and runs the air pump, the water pump, the LED chromatherapy light and the heated seat from labeled ports. A green light on the box shows that power is reaching it.

The master control box video on this page shows two of these boxes side by side. The presenter points to the heated seat connectors, the air pump and water pump ports, the nipples for the push button air hoses and the power inlet on each box. One box carries a standard three prong 15 amp plug, and the other carries a 20 amp plug with one blade turned sideways. That difference is the reason the amp question comes up so often after delivery.

On the fullest single-seat package, the digital controller sheet for the Transfer60, TransferXXL and Ultimate, the surface heater pads and the surface key pad, labeled Heat Keypad, are two of the ten numbered components, and the whole stack runs on two dedicated GFCI protected 20 amp, 120 volt lines. What the Full Digital Controller Package Schematic Shows walks through that sheet component by component.

How the Heated Seat Changes the Line Count

Ella publishes line counts by therapy package, never by model name. Each labeled cord on the tub needs its own dedicated 20 amp, 120 volt GFCI protected circuit that shares nothing with any other appliance, and on a two line tub the cord stickers read Line 1 20 Amp and Line 2 20 Amp. The table below collects the published counts.

Therapy packagePublished dedicated linesWhat it means for the rough-in
Hydro only, air only, or hydro plus airOne 20 amp, 120 volt GFCI circuitA single receptacle in or behind the equipment compartment
Hydro plus air with heated seat (the heated seat variants)Two 20 amp, 120 volt GFCI circuitsThe heated seat option moves a one line tub to two lines
Hydro plus microbubble, or hydro plus independent foot massageTwo 20 amp, 120 volt GFCI circuitsSame count as the heated seat variants
Air + Hydro + Hydro Foot + Microbubble + Heated Seat and Back with digital controller (Transfer60, TransferXXL, Ultimate)Two 20 amp, 120 volt GFCI circuitsThe fullest single-seat stack still fits on two lines
ShaK and Big4One, Air + Hydro + Hydro Foot + MicrobubbleThree 20 amp, 120 volt GFCI circuitsThe only single-seat schematic with three wall outlets
Two-seat tubs with the full packageThree 20 amp, 120 volt GFCI circuitsOne receptacle per labeled cord
Soaking tub with no pumpsNo outlet neededDrains are gravity driven, so there is nothing to plug in

For your electrician the takeaway is simple. If your order is air plus hydro with the heated seat option, plan for two dedicated 20 amp GFCI circuits rather than one. Which pump or box lands on which cord is set at the factory and printed on the cord labels and on your schematic, so there is no wiring decision to make inside the tub. The only site decisions are where the receptacles go and whether the GFCI protection sits at the breaker or at the receptacle; one or the other is sufficient. Landing both labeled cords on a single GFCI trips the breaker as soon as the second pump starts.

Can the Circuit Be 15 Amp?

The published standard is 20 amps on every dedicated line. The GFCI circuits guide allows that a 15 amp line can work on some lighter packages, and in the same breath lists a 15 amp line where 20 amps is specified as one of the likely causes of trouble. Two practical points decide it on a heated seat tub.

  • The plug may not fit. Some master control boxes carry a 20 amp plug with one horizontal blade, and that plug needs a 20 amp receptacle. In the video the presenter holds up exactly that plug and says to ask for a 20 amp receptacle at the hardware or electrical store. If only one system runs after installation because its cord was the only one that fit, the fix is a 20 amp receptacle, never an adapter or an extension cord.
  • The box that powers the heated seat also powers the pumps. The heater pads share the master control box with the air pump and the water pump, and the published requirement for every labeled cord is 20 amps. A 15 amp line where 20 amps is specified is a documented cause of trouble, so hold to 20 amps unless the team confirms otherwise for your specific package.

Before rough-in, ask the team at ellasbubbles.com/support or (800) 480-6850 to email the electrical diagram for your model and package. It shows the line count and the outlet location, so your licensed electrician can install the right receptacles the first time. Ella does not send technicians; the wiring is done by a local licensed electrician.

Placing the Outlets for a Heated Seat Tub

The receptacles belong under the seat area, inside or directly behind the equipment compartment, so the pump, heater and control box cords reach without extensions. Keep other appliances at least 3 feet from the tub. Put one GFCI on each line, at the breaker or at the receptacle, and do not double up. On a three pump tub the third pump is powered with the in-line water heater on a separate line, so there are more cords than control box ports; count the labeled cords, not the ports. Which Cord Plugs In Where on My Walk-In Tub? matches every cord to its outlet and shows the push button air hoses seating on the control box nipples.

The heated seat is also an option on the largest tubs. The ShaK spec sheet lists an optional heated seat and backrest below its two hydro pumps, air pump, in-line heater and microbubble system, and the ShaK and Big4One schematic already calls for three dedicated lines, labeled #1, #2 and #3, each 20 amp and 120 volt. What electrical circuits does the Ella ShaK need for all four therapies? and the Shak and Big4One digital schematic page cover those two tubs in detail.

Using the Heated Seat Once It Is Wired

Push the button once and the heated seat activates. Ella suggests turning it on 10 to 15 minutes before you enter the tub for maximum comfort. It turns off automatically after 20 minutes, and one more push turns it back on. The short heated seat video shows that sequence. If the seat never warms while the pumps run, check the green light on the master control box and the GFCI first, then confirm the heater pad connector is seated on its labeled port before opening a ticket with your serial number, therapy package and a photo of the control box with every cord visible.

Video
Chapters in this video
  1. 0:00 Introduction to Master Control Boxes The video introduces two master control boxes that manage the massage systems and heated seat in Ella's Bubbles walk-in tubs.
  2. 0:16 First Control Box Connections This section details the connections for the heater pads, air pump, water pump, and the main power input for the first control box.
  3. 0:41 Control Connectors and Switches The video explains where to connect the push buttons for the water pump, air blower, LED light, and the digital control keypad.
  4. 1:36 Second Master Control Box The second master control box is presented, showing its connections for the heated seat, air pump, water pump, and main power inlet.
  5. 1:55 20 Amp Power Connector The video highlights the 20 amp power connector for the second control box and explains how to identify its unique plug.

Watch: Master Control Box Explanation with chapters and a full transcript.

Video

Watch: Heated Seat Option for Your Walk-In Tub: Relaxed Bathing | Ella's Bubbles with chapters and a full transcript.

Video
Chapters in this video
  1. 0:00 Electrical Components Are Marked Ella's Bubbles ensures all electrical components are clearly marked and easily accessible for installation.
  2. 0:13 Dedicated GFCI Protected Outlets Your contractor connects the tub to your home's power supply using dedicated GFCI protected outlets.
  3. 0:25 GFCI Protected Breakers The breaker box must utilize GFCI protected breakers with the appropriate amperage value for your tub's components.
  4. 0:40 Enjoy Your Walk-In Tub Proper installation provides years of reliable, trouble-free walk-in tub enjoyment.

Common Questions

Does the heated seat have its own power cord to the wall?
No. The surface heater pads and the heat keypad connect to the master control box, which also runs the air pump, the water pump and the LED light from labeled ports. The box takes power at one inlet, and that inlet is the cord that goes to the wall.
Can I run a heated seat tub on a 15 amp GFCI outlet?
The published standard is a dedicated 20 amp, 120 volt GFCI protected circuit for every labeled cord. A 15 amp line can work on some lighter packages, but it is listed as a likely cause of trouble where 20 amps is specified, and a 20 amp plug will not fit a 15 amp receptacle. Ask the team for the diagram for your package before your electrician runs the wire.
Why does the master control box plug not fit my receptacle?
Some master control boxes carry a 20 amp plug with one blade turned horizontal. That plug needs a 20 amp receptacle, which your electrician can install in place of the 15 amp type. Never use an adapter or an extension cord to make it fit.
Can both labeled cords share one 20 amp GFCI circuit?
No. Each labeled cord needs its own dedicated circuit that shares nothing with any other appliance. Two cords on one GFCI trip the breaker as soon as the second pump starts.
How long does the heated seat stay on after I press the button?
It turns off automatically after 20 minutes. Push the button once more to turn it back on, and turn it on 10 to 15 minutes before you enter the tub for the most comfort.
How many circuits does the ShaK or Big4One need with a heated seat?
The ShaK and Big4One schematic calls for three dedicated 20 amp, 120 volt GFCI lines, labeled #1, #2 and #3, for their air, dual hydro and optional microbubble stack, and the ShaK spec sheet lists the heated seat and backrest as an option on that tub. Share the schematic PDF with your electrician, and ask the team to confirm the count for your exact order.

About this guide. Answers in the Ella’s Bubbles Support Center are compiled from real conversations with tub owners, our technicians’ notes and the product documentation, then reviewed by our team. Tub models and options have evolved over the years, so a detail here may differ slightly from your exact tub. If something looks different on yours, send us your serial number and a specialist will confirm it for your model.

Did this solve your question?

If not, open a ticket and our team will pick it up from here.

Open a Support Ticket